Basic Info.
Model NO.
ISO9001 factory sale three phase electronic active
Installation
Indirect Connected
Usage
Multi-Functional Energy Meter, Watt-Hour Meter, Prepayment Meter, Reactive Energy Meter
Electric Equipment
Three-phase Three-wire
Theory
Machine-electric Type
Power Meter Connection
Terminal
Measured Signal
Pulse Peak
Certification
RoHS, ISO, CE
Customized
Non-Customized
Product Description
Product Name: 3 phase din rail mount digital LCD display multi-tariff energy meter
APPLICATION |
Three phase three wire or four wire DIN rail watt hour meter is used to measure active energy consumption. Din Rail energy meter is a new modern smart meter: three-phase ( 7modular ), using advanced technology, ensure quality and stability, also has good resistance electromagnetic interference performance, low power consumption, confirm to IEC62052-11 international standards, which has following advantages: small size, light weight, high precision, suitable for office building and shopping mall, Air port, Distribution box. |
FUNCTIONS AND FEATURES |
♦35mm standard DIN rail installation, complying with standard DIN EN50022. ♦7 modular 125mm width. ♦Cyclometer display ( 5+1 digits ) or LCD display ( 6+2 digits ) ♦Single direction measure active power consumption. comply with standard IEC62053-21, IEC62052-11. ♦Adopts high reliable and long-life electric components, high overload, no need calibrate for long-term operation. ♦LED indicates phase A, B, C, ,impulse and reverse. ♦Automatically detect direction of load current, If the LED "REV" lights means the load current is reverse. ♦Single direction three components measure three phase four (three) wire active energy consumption. It is nothing with direction of the flow of load current,complying with standard IEC62053-21,IEC62052-11. ♦Measure three phase three wire active energy or three phase four wire active energy. ♦Directly connect operation maximum 100A or choose CT operation ( 1.5-6A ) Optional Functions ♦Communicate data collection via RS485 Modbus RTU protocol ♦DLT645-1997 protocol has Optical port ♦Three phase Voltage (V); Current (A); Frequency ( Hz ); Power (KW); Power factor (COS) ♦Remote data transfer, remote control by RS485 via relay to control the meter on or off . |
TECHNICAL PARAMETERS |
Accuracy | Class 1.0 |
Rated voltage | 3*57.5/110V, 3*110/200V, 3*220/380V, 3*230/400V, 3*240/415V |
Operation voltage range | Un±20% |
Insulation capabilities | AC voltage withstand 4kV for 1 minute; Impulse voltage withstand 6kV - 1.2/50μs waveform |
Rated current(A) | 3*1.5(6), 3*5(30), 3*10(60), 3* 20(80), 3*30(100). |
Operation current range | 0.05Ib~ Imax |
Starting current | 0.004Ib |
Rated frequency | 50Hz or 60 Hz |
Internal power consumption | Voltage Circuit ≤1.0W 5VA; Current Circuit ≤1VA(Ib) |
Interface | Optical coupler (So corresponding to DIN 43864) |
Impulse valence Ra | 0,5 or 1.0 Wh/imp |
Max.operation temperature | -20°C ~ +75°C |
Relative humidity | ≤ 85% |
Dimension | 88mm*68mm*125mm |
ac din rail three phase active &reactive electronic kwh energy meter
Pls Note: when you place an order,pls leave a message to us:
1.what is the current,voltage,frequency and constant do you need?
2.what is the communication protocol do you need?
we have three kinds of protocol,that is Modbus,DL/T645 and IEC1107.
Or pls contact our salesman.
Thanks in advance.
• Phase loss with 3 x LED display for L1,L2,L3
• Pulse display with 2 x LED display for test & output
• Reverse direction display with LED
• Small modular size, DIN rail mounted.
• Easy installation to distribution boards, load center, miniature & etc.
by identifying where energy is being used.
• 7 digits LCD display with EEPROM displayable even power failure.
• Typical accuracy class 1.0 IEC1036
• 3Ph3W, 3Ph4W. Voltage 100V, 380V, 220/380V, 57.5/100V & etc.
• Current 1.5(6), 5(30), 10(50), 15(90), 20(100), 5(40),5(100)A.
• Optional pulse output or RS485 for remote metering.
• Tropical and Trivialized meters: 95% relative humidity.
Application.
The electronic electric meter registers energy consumption in alternating current
systems. Its compact, rugged design allows for universal implementation in industrial
systems, at construction sites, in the office, at leisure facilities and in the household.
The meter can be mounted in any position on a top-hat rail per EN 50022 fastened.
Installation of the energy meter at incoming power supply lines, distribution centers or
directly at power consumers allows for the individual acquisition of energy data, as
well as targeted billing of energy costs.
Technical Data.
Rated Current(A) | 3/1.5(6),3/5(20),3/10(40),3/15(60),3/20(80),3/30(100) |
Rated Voltage(V) | Three-phase three-wire 3x100V or 3x380V Three-phase four-wire 3x200/380V or 3x57.7/ 100V |
Rated Frequency(Hz) | 50 or 60 |
(Accuracy class) | 1 Class or Class 2
|
Functions and features
1.With ADE7755 chip to measure positive and negative active power in the same direction to
prevent energy theft by current reverse connection.
2.Power carrier wave communication function:used for setting and reading meter parameters.
3.Relay can be operated in the watt-hour meter ;
4.Communication speed rate:Synchronous communication, 500bps;
5.Communication distance:500m (between every two connection points);
6.The meter has 4 degree carrier relay function to expand communication distance;
7.Communication protocol:carrier wave communication protocol;
8.Power-off control function:remote power on/off control through carrier.
9.Display mode: register, LCD.
10. 485 interface.
Cell phone:+86-13757756659
Web:https://dingyi-electrical.en.made-in-china.com
Add: Liushi Town, Yueqing, wenzhou .Zhejiang, 325600 China